Urban construction tends to high level, people’s living with water will need to be promoted, air conditioning chilled water, cooling water circulation system pump use more and more widely. However, thenoise and vibration caused by the problem of the environment are also put forward to control and protection. Leading to a unit and the pumping station building to produce vibration caused by many reasons, some factors between both interrelated and interact with each other. And briefly, mainly thefollowing four aspects.
1, electrical aspects
Motor is the main equipment of the unit, the internal magnetic force of the motor and other electrical systems, often caused by vibration and noise.
2, mechanical aspects
Motor and pump rotation parts quality imbalance, shoddy, installation of poor quality, asymmetric unit axis, a swing degree exceeds the allowable value, parts of mechanical strength and poor stiffness, bearing and sealing parts wear and damage, and the critical speed of the pump appears and the natural frequency of the unit rate difference caused by the resonance etc., will produce strong vibration and noise.
3, hydraulic aspects
Pump inlet velocity and pressure distribution is not uniform pump import and export liquid pressure pulsation, liquid flow around and drift and flow separation, non fixed conditions and a variety of
causes for pump gas turbidity are a common cause of the vibration of the pump unit. Pump start and shutdown, the valves open and close, changing working condition and accident emergency stop dynamic transition process caused by pipeline the rapid change of the pressure and the water hammer effect, often lead to vibration of the pump and crew.
4, water workers and other aspects
Set inlet flow design unreasonable or does not match with the unit, a water pump submerged depth properly, and the unit startup and shutdown order is not reasonable etc., so that the deterioration
of water conditions, vortices, induced air turbidity or aggravate unit and pump vibration. The damage siphon vacuum drying unit in startup, if hump section of the air entrainment difficult to form a long
siphon; beat the door cutout of the unit take door design unreasonable, open and closed, continue to impact the flap valve seat; foundation to support the pump and motor occurred uneven settlement or
foundation of rigid poor reasons, will also lead to unit vibration. From this, we can get the conclusion: the vibration of the water pump is very many, many of which are inevitable. And in fact,whether from the design of the production link, or hydraulic design, can not completely eliminate the vibration of the pump.Therefore, it is very important to implement the vibration isolation of the water pump through the installation of inertia base and the spring vibration isolator and the rubber isolator.

以上【样册P65】Vibration analysis of water pump信息来源于上海淞江减震器集团有限公司官方网站,如需了解更多减振信息请点击:弹簧减震器查询,欢迎新老客户到我厂实地参观考察,电话:021-33666667。










最新推荐:
  • ·【保定希尔顿酒店项目】弹簧减震器合同
  • ·上海金属软管安装使用注意事项
  • ·【耐磨】单球耐磨橡胶接头“增加耐磨装置”
  • ·金属软管安装上还没试压就漏水问题分析(被现场作业烧破)
  • ·【样册P26】可曲挠橡胶接头质保承诺
  • ·0~300游标卡尺检定证书
  • ·上海淞江ZTA型水泵弹簧减震器检验报告
  • ·【北京金融科技中心项目】橡胶接头合同
  • ·【枣庄八一水煤浆热电项目】橡胶接头合同
  • ·【阿里巴巴西溪六期项目】弹簧减震器合同